• CPU1515t-2pn Centralprocessingunit6es7515-2TM01-0ab0
  • CPU1515t-2pn Centralprocessingunit6es7515-2TM01-0ab0
  • CPU1515t-2pn Centralprocessingunit6es7515-2TM01-0ab0
  • CPU1515t-2pn Centralprocessingunit6es7515-2TM01-0ab0
  • CPU1515t-2pn Centralprocessingunit6es7515-2TM01-0ab0
  • CPU1515t-2pn Centralprocessingunit6es7515-2TM01-0ab0

CPU1515t-2pn Centralprocessingunit6es7515-2TM01-0ab0

Task: Program
Structure: Combination
Mathematical Model: Linear
Signal: Continuous
Function: Automatic Control
Certification: CCC, ISO: 9001, CE
Customization:
Gold Member Since 2024

Suppliers with verified business licenses

Shanghai, China
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
to see all verified strength labels (13)

Basic Info.

Model NO.
6ES7515-2TM01-0AB0
Condition
Used
Customized
Customized
Material
Stainless Steel
Transport Package
Express
Specification
15.60 x 16.10 x 8.30
Trademark
siemens
Origin
Germany
HS Code
8504409999
Production Capacity
50000individual

Product Description

Data: 6ES7515-2TM01-0AB0SIMATIC S7-1500, CPU 1515T-2 PN, Central Processing Unit, with 750 KB working memory for programs and 3 MB for data, 1st port: PROFINET IRT with dual ended switch, 2nd port: Ethernet, 30 ns Bit Performance, requiring SIMATIC storage card general information Product Type Mark CPU 1515T-2 PN Hardware Function Status FS04 Firmware Version V2.9 Product Features The I&M data is; I&M0 I&M3 Clock synchronization mode is:; Distributed and centralized; STEP 7 TIA terminal with maximum organizational block, 6 500 µ s cycles (distributed) and 1 ms (centralized) with accompanying program package, configurable/integrated, with version V17 (firmware V2.9)/V14 (firmware V2.0) and above configuration control through data set display screen. Line [cm] 6.1 cm operation element key quantity 6 operation mode switch 1 power supply voltage rating (DC) 24 V allowable range, lower limit (DC) 19.2 V allowable range, upper limit (DC) 28.8 V reverse polarity protection is for power supply and Voltage circuit breaker crossover Power outage/power outage crossover time 5 ms Repetitive rate, maximum value 1/s Input current consumption current (rated value) 0.8 A Connect current, maximum value 2.4 A; Rated value I ² T 0.02 A ²· The feeding power on the s power backplane bus is 12 W, and the power consumption of the backplane bus (reaches equilibrium) is 6.2 W. The power loss is typical, with a value of 6.3 W. The memory 6ES75152TM010AB0 starts from 1/9, 2024/11, and the right to change is reserved ©  Copyright Siemens SIMATIC Memory Card Slot Quantity 1 requires SIMATIC Memory Card to be used as storage Integrated (for program) 750 kbyte Integrated (for data) 3 Mbyte Load Memory Pluggable (for SIMATIC Memory Card), maximum value 32 Gbyte Buffer Maintenance-free CPU processing time for bit operations, typical value 30 ns for word operations, typical value 36 ns for fixed-point operations, typical value 48 ns for floating-point operations, typical value 192 ns CPU - Number of component elements (total) 8000; Program blocks (OB, FB, FC, DB) and UDTDB Number range 1 60 999; Divided as follows: 1 Number range for 59 999 and data blocks created by SFC 86: 60000 60 999 Capacity, with a maximum value of 3 Mbytes; For a database with absolute addressing, the maximum capacity is 64 KBFB Number range 0 65 535 Capacity, maximum value 500 kbyteFC Number range 0 65 535 Capacity, maximum value 500 kbyte OB Capacity, maximum value 500 kbyte Number of recyclable OBs 100 Number of time alarm OBs 20 Number of delayed alarm OBs 20 Number of wake-up warning OBs 20; With the largest organizational block, 3 cycles of 500 µ s Number of process alarm OBs 50 Number of DPV1 alarm OBs 3 Number of isoch ISO on TCP (RFC1006) is - data degree with a maximum value of 64 kbyte UDP is - data degree with a maximum value of 2 kbyte; 1472 bytes during UDP multicast - UDP Multicast is; Up to 5 circuits DHCP is DNS is SNMP is DCP is LLDP is encryption is; Optional network server HTTP is available; The standards and HTTPS are:; What is the permit for the operation of the OPC UA group during standard operation; Require a "medium" license OPC UA client is - application program verification is - security policy can be used. Security policy is available, Basic128Rsa15, Basic256Rsa15, Basic256Sha256- self verify "anonymity" or verify through username and password - number of connections, with a maximum value of 10- number of nodes that the client can connect to. It is recommended to have a maximum value of 2000- call OPC_UA-NodeGetHan each time. The number of elements in dleList/OPC_UA-ReadList/OPC_UA_WriteList, with a maximum value of 300- the number of elements in each call to OPC_UANameSpaceGetIndexList, with a maximum value of 206ES75152TM010AB0 starting from June 9, 2024/4/11. Change rights reserved ©  Copyright Siemens - The number of elements in each call to OPC_UA-MethodGetHandleList, with a maximum value of 100- The number of client instructions that can be called simultaneously for session management, each connection, with a maximum value of 1- The number of client instructions that can be called simultaneously for data access, each connection, with a maximum value of 5- The number of nodes that can be registered, and a maximum value of 5000- The method of calling OPC_UA-MethodCall that can be registered. The quantity, with a maximum value of 100- the number of input/output terminals for adjusting OPC_UA-MethodCall, with a maximum value of 20 The OPC UA server is; Data access (read, write, subscribe), method calling, user-defined address space - Application verification is - Security policy can be used. Security policy can be used, Basic128Rsa15, Basic256Rsa15, Basic256Sha256- Self verification of "anonymity" or verification through username and password - GDS holder (certificate management) - Number of sessions, with a maximum value of 48- Number of accessible variables, and a maximum value of 100000- The number of registrable nodes, with a maximum value of 20000- the number of subscriptions per session, a maximum value of 20- the scanning interval, a maximum value of 100 ms - the sending interval, a maximum value of 200 ms - the number of servo programs, a maximum value of 50- the number of input/output terminals for each servo program, a maximum value of 20- the number of monitored items, and a recommended maximum value of 2000; for 1-second sampling interval and 1-second sending interval - the number of server connections, and a maximum value of 20- the number of monitored items. There are 10 types of "Server Connection"/"Matching Specification" and 20 types of "Benchmark Domain Name Space" in the 68th percentile, which define the number of nodes when the server is connected, Maximum value 5000 Alarm and conditions are -200 program messages -100 system diagnostic messages - Other protocols MODBUS is; MODBUS TCP isochronous mode equidistance is the number of registrable sites for the S7 message function message function, with a maximum value of 64 program messages being the number of configurable program messages, and a maximum value of 10000; The number of program messages that can be loaded in the RUN state is generated through modules such as "Program-Alarm", ProDiag, or GRAPH. The maximum value is 5000, which is the amount of information that is active at the same time. The maximum value is 800 program messages, 200 system diagnostic messages, and 160 messages for motion technology objects. The debugging function test is to jointly debug (program group); What is the maximum allowed online access to 8 process configuration system components at the same time; Up to 8 (total of all ES clients) can be stopped at the same time for each step. The number of stops is 8. Status/Control minimum cycle time with adjustable upper limit. The width of the ruler is 70 mm, the degree is 147 mm, the depth is 129 mm, the weight is about 830 g

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2024

Suppliers with verified business licenses

Trading Company
Number of Employees
12
Year of Establishment
2021-11-26