Customization: | Available |
---|---|
Application: | High-performance Transducer, Three Phase Transducer |
Output Type: | Dual |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
This Altistart 22 soft starter can feed 3-phase asynchronous motors in supply line connection. It has a rating of 17A and 230V to 440V, a rated power up to 7.5kW (400V to 440V in supply line) and up to 15kW (440V in motor delta connection). It is designed for simple and complex machines such as centrifugal and piston pumps, fans, screw compressors and material handling equipment. Slim form factor improves versatility; allows mounting in frames of any kind of machines. It features an Integrated bypass, this reduces noise and decreases heat dissipation. Compatibility with SoMove software allows configurations and settings to be easily transferred, meaning spares can be quickly installed. It provides smooth starting for your machinery, avoiding mechanical stresses and extending their service life.
Range of Product | Altistart 22 |
---|---|
Product or Component Type | Soft starter |
Product destination | Asynchronous motors |
Product Specific Application | Pumps and fans |
Component name | ATS22 |
Phase | 3 phase |
[Us] rated supply voltage | 230...440 V - 15...10 % |
Motor power kW | 4 kW 230 V 7.5 kW 400 V 7.5 kW 440 V |
Factory setting current | 14.8 A |
Power dissipation in W | 39 W for standard applications |
utilisation category | AC-53A |
Type of start | Start with torque control (current limited to 3.5 In) |
IcL starter rating | 17 A connection in the motor supply line for standard applications |
IP Degree of Protection | IP20 |
Assembly style | With heat sink |
Function Available | Internal bypass |
Supply voltage limits | 195…484 V |
Supply frequency | 50...60 Hz - 10...10 % |
Network Frequency | 45...66 Hz |
Device connection | In the motor supply line To the motor delta terminals |
[Uc] control circuit voltage | 230 V - 15...10 % 50/60 Hz |
Control circuit consumption | 20 W |
Discrete output number | 2 |
Discrete output type | Relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O Relay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O |
Minimum switching current | 100 mA 12 V DC relay outputs) |
Maximum switching current | 5 A 250 V AC resistive 1 relay outputs 5 A 30 V DC resistive 1 relay outputs 2 A 250 V AC inductive 0.4 20 ms relay outputs 2 A 30 V DC inductive 7 ms relay outputs |
Discrete input number | 3 |
Discrete input type | LI1, LI2, LI3) logic, 5 mA 4.3 kOhm |
Discrete input voltage | 24 V <= 30 V |
Discrete input logic | Positive logic LI1, LI2, LI3 < 5 V <= 2 mA > 11 V, >= 5 mA |
Output current | 0.4...1 Icl adjustable |
PTC probe input | 750 Ohm |
communication port protocol | Modbus |
Connector Type | 1 RJ45 |
Communication data link | Serial |
Physical interface | RS485 multidrop |
Transmission Rate | 4800, 9600 or 19200 bps |
Installed device | 31 |
Protection type | Phase failure line Thermal protection motor Thermal protection starter |
Marking | CE |
Type of cooling | Forced convection |
Operating position | Vertical +/- 10 degree |
Height | 10.43 in (265 mm) |
Width | 5.12 in (130 mm) |
Depth | 6.65 in (169 mm) |
Net Weight | 15.43 lb(US) (7 kg) |
Motor power range AC-3 | 4…6 kW 200…240 V 3 phase 7…11 kW 380…440 V 3 phase |
Motor starter type | Soft starter |
Electromagnetic compatibility | Conducted and radiated emissions level A IEC 60947-4-2 Damped oscillating waves level 3 IEC 61000-4-12 Electrostatic discharge level 3 IEC 61000-4-2 Immunity to electrical transients level 4 IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 IEC 61000-4-3 Voltage/current impulse level 3 IEC 61000-4-5 |
Standards | IEC 60947-4-2 |
Product Certifications | UL GOST CSA CCC C-tick |
Vibration resistance | 1 gn 13…200 Hz)IEC 60068-2-6 1.5 mm 2…13 Hz)IEC 60068-2-6 |
Shock resistance | 15 gn 11 ms IEC 60068-2-27 |
Noise level | 45 dB |
Pollution degree | Level 2 IEC 60664-1 |
Relative humidity | 0…95 % without condensation or dripping water IEC 60068-2-3 |
Ambient air temperature for operation | 14…104 °F (-10…40 °C) without derating) 104…140 °F (40…60 °C) with current derating 2.2 % per °C) |
Ambient Air Temperature for Storage | -13…158 °F (-25…70 °C) |
Operating altitude | <= 3280.84 ft (1000 m) without derating > 3280.84...< 6561.68 ft (> 1000...< 2000 m) with current derating of 2.2 % per additional 100 m |
Product Certifications | CE cULus CCC UKCA RCM EAC DNV ABS BV CCS |
---|
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 11.02 in (28.0 cm) |
Package 1 Width | 8.66 in (22.0 cm) |
Package 1 Length | 13.19 in (33.5 cm) |
Package 1 Weight | 12.34 lb(US) (5.597 kg) |
Main products: frequency converters, controllers, drives, switches, redundant systems, power modules, system software, industrial Ethernet, central processing units, low-voltage, logic control modules
The delivery date starts with a one-year warranty, and human factors are no longer covered by the warranty.